FLDC series 4-20mA electromagnetic flowmeter is a fully intelligent flowmeter developed by our company with the most advanced technology at home and abroad. It has high measurement accuracy, high reliability, good stability and long service life. In the process of designing product structure, material selection, manufacturing process, production assembly and factory test, we are very meticulous and strict. We have also designed a set of the most advanced production equipment and flow calibration device specially for electromagnetic flowmeter, so as to ensure both software and hardware. Long-term high quality of certificate products

 

Output signals

·4-20mA output:suitable for long-distance analog signal transmission; ·Frequency/pulse output:used for meter calibration and accumulative flow output;

·RS485 communication:It can support networking of multiple electromagnetic flowmeters and long-distance data transmission; Users need to select output signals according to actual conditions and supporting equipment.

 

Selection of grounding ring

· Grounding ring is used to ground the measured medium to improve the stability of the electromagnetic flowmeter measurement. Because the grounding ring needs to be in contact with the measured medium, there is a possibility of corrosion and wear of grounding ring, which needs to be replaced periodically.

· Instead of using grounding ring, FLDC series electromagnetic flowmeter has adopted grounding electrode to guarantee long-term stability of grounding and high accuracy. If the stray current is too large to guarantee the normal measurement of the electromagnetic flowmeter, such as the leakage current of the electrolytic cell along the electrolyte,a grounding ring would be recommended to be used.

· Some small-caliber electromagnetic flowmeters have only two electrodes, and users can choose double grounding rings according to site requirements.

· When installing the grounding ring, the grounding ring needs to be put on the right position to avoid affecting the flow field of the measured medium.

 

Technical Parameters

Executive standard

JB/T9248-1999

Measured medium

Conducting liquid and slurry

 Type

 Piping Type   electromagnetic flowmeter

 Type structure

 Integrated typeSplit type

Nominal diametermm

 6101520253240506580100, 125150200250300350400500.600700800900100012001400160018002000

Nominal pressure

 DN6-DN80

 DN100DN150

 DN200-DN1000

4.0MPa

1.6MPa

1.0MPa

 Special pressurecan be customized Velocity range

Velocity range

 0-10m/s Can be   set

Medium conductivity

 25u5/cmActual conductivity 250uS/cm

Accuracy

±0.2%±0.5%

Ambient temperature

  -20-50

Highest medium temperature

 CR chloroprene   rubber linerCR

0-65

 PolyurethanePU

0-65

 PolytetrafluoroethylenePTFE

-25-+140

 Fluorinated   ethylene propylene

 -25-+120

 PerfluoroalkoxyPFA

-25--180

Material of electrodes

 3161Hastelloy B/CTantalumTa),TitaniumTi),PlatinumPt

Form of electrodes    

 Stationary typescraper typedismountable type

Number of electrodes

Standard 2 electrodesshould be configuration according to caliber

Flange standard

GB9119Other standard   can be customized

 Flange material

 carbon steelstandard),stainless steeloptional

Grounding ring material

 DN15-DN10101Cr1SNi9Tistainless steeletc.

 Housing matcrial  

 Carbon steelstardard),stainless steeloptional

 Supply power

 220VAC24VDC

Output signal

 4-20mAPulseFrequencyRS485

Digital communication

RS-485HART

 Cable entry size

  M20x1.5Standardnylon waterproof   connector.optionalexplosion-proofmetal connector

Level of protection

 Split type   convertor

 IP65

  Split type   sensor

IP65-IP68

 integrated type   convertor

 IP65

Wiring lengthsplit type)

 Standard 10m.The   distance between coverter and sensor is generally no more than 30m.

Explosive-proof grade

 Exd II CT3-6

 Flow direction

 Forward and   reverse

Constant current load

750 Ω

 Storage   temperature

  -40-60

 Relative   humidity

 5-95%

Alarm settingnormally open

Empty pipeexcitationupper and lower   limit